UkraineDnipro City

comerc@elemark.com
+38 098 606-33-15
logologo-w
  • en
  • ua
  • Ноme
  • Products
    • Measuring transformers
    • Power transformers
    • Current transformers
    • Switching pads
    • Voltage transformers
  • Certificates
  1. Home
  2. Products
  3. Voltage transformers
  4. VTU (VTU-SF) Voltage Transformer

VTU (VTU-SF) Voltage Transformer

The VTU is a single-phase grounded voltage transformer (the VTU-SF version is equipped with a fuse device).

The transformer is designed for transmitting measurement signals to metering instruments, protection and control devices, and for isolating secondary circuits from high voltage in indoor AC switchgear operating at 50 Hz.

The technical specifications comply with the requirements of DSTU EN 61869-3:2017.

The transformer is manufactured in placement category C1 according to DSTU EN 60654-1:2022 and is intended for operation under the following conditions:

  • – altitude above sea level – not more than 1000 m
  • – relative humidity – up to 98% at 30 °C
  • – upper operating ambient temperature – +50 °C
  • – lower operating ambient temperature – −45 °C
  • – ambient environment – non-explosive, free of dust, chemically active gases or vapors in concentrations that may damage metal coatings or insulation
  • – installation position – any

Insulation thermal class – B.

Type Examination Certificate (Module B) No. UA.TR.001 34-25 Rev.0, reference number 29/3/B/12/044-25.

  • Survey letter
  • Contact a specialist
Highest equipment voltage Um, kVRated primary voltage UPr, kVRated secondary voltage for measurement USr, VRated secondary zero-sequence voltage USr, VPower frequency withstand voltage (primary), kVLightning impulse withstand voltage (peak), kV
7,26/√3; 6,3/√3; 6,6/√3100/√3; 110/√3; 120/√3100; 110; 120; 100/√3; 110/√3; 120/√3; 100/3; 110/3; 120/32060
1210/√3; 10,5/√3; 11/√32875

Технічні характеристики

Highest equipment voltage Um, kV7,2; 12
Rated voltage factor FV1.9 (8 hours)
Rated frequency fR, Hz50
Number of secondary windings1, 2, 3
Accuracy classes (measurement secondaries)0,5; 1,0; 3,0
Accuracy classes (protection and zero-sequence)3Р; 6Р
Rated burden of measurement windings (cos φ = 0.8), VA15, 25, 30, 50, 75*, 100* 50, 75, 100, 150* 75, 100, 150, 200*
Rated burden of protection / zero-sequence windings (cos φ = 0.8), VA50, 100, 150, 200, 300
Thermal limit power, VA650
Weight, kg (max)25
* Transformers with rated primary voltages 6/√3; 6.3/√3; 6.6/√3 are not manufactured.
Application form!
send
This form is for sending a request for a call back.
Contacts
  • +38 098 606-33-15
  • Dnipro CityAddress
  • comerc@elemark.com
  • ©ELEMARK2025

Pages
  • Ноme
  • Products
  • Certificates
PRODUCTS
  • Measuring transformers
  • Power transformers
  • Current transformers
  • Switching pads
  • Voltage transformers
Powered By Blade.MSP ® from BrainTEC ™